Parameter Range Resolution Accuracy Wavelength Method Reagent Code Chlorine, Total 0.00 to 5.00 mg/L (as Cl±) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the EPA DPD Method 330.5 HI93701-T Reagents for 300 tests (liquid) HI93711-01 Reagents for 100 total tests (powder) HI93711-03 Reagents for 300 total tests (powder) Chlorine, Total Ultra High Range 0 to 500 mg/L (as Cl±) 1 mg/L ±3 mg/L ±3% of reading at 25 °C 525 nm Adaptation of the Standard Methods for Examination of Water and Wastewater, 20th Edition, 4500-Cl HI95771-01 Reagents for 100 tests HI95771-03 Reagents for 300 tests Chromium (VI) Low Range 0 to 300 μg/L (as Cr(VI)) 1 μg/L ±10 μg/L ±4% of reading at 25 °C 525 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1687 Diphenylcarbohydrazide Method HI93749-01 Reagents for 100 tests HI93749-03 Reagents for 300 tests Chromium (VI) High Range 0 to 1000 μg/L (as Cr(VI)) 1 μg/L ±5 μg/L ±4% of reading at 25 °C 525 nm Adaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide Method HI93723-01 Reagents for 100 tests HI93723-03 Reagents for 300 tests Chromium (VI)/Total (13 mm Vial) 0 to 1000 μg/L (as Cr) 1 μg/L ±10 μg/L ± 3% of reading 525 nm Adaptation of the Standard Methods of the Examination of Water and Wastewater, 22nd Edition, 3500-Cr, Diphenylcarbazide Method HI96781-25 Reagents for 25 tests Chemical Oxygen Demand Low Range (13 mm Vial) 0 to 150 mg/L (as O±) 1 mg/L ±5 mg/L or ±4% of reading at 25 °C, whichever is greater 420 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754A-25 Reagents EPA Low Range for 25 tests HI93754D-25 Reagents Hg Free Low Range for 25 tests HI93754F-25 Reagents ISO Low Range for 25 tests Chemical Oxygen Demand Medium Range (13 mm Vial) 0 to 1500 mg/L (as O±) 1 mg/L ±15 mg/L or ±4% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754B-25 Reagents EPA Medium Range for 25 tests HI93754E-25 Reagents Hg Free Medium Range for 25 tests HI93754G-25 Reagents ISO Medium Range for 25 tests Chemical Oxygen Demand High Range EPA (13 mm Vial) 0 to 15000 mg/L (as O±) 1 mg/L ±150 mg/L or ±2% of reading at 25 °C, whichever is greater 610 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754C-25 Reagents for 25 tests Chemical Oxygen Demand Ultra High Range (13 mm Vial) 0.0 to 60.0 ppt (as O±) 0.1 ppt ±0.5 ppt ±3% of reading @ 25°C 610 nm Adaptation of the EPA 410.4 Approved Method for the COD Determination on Surface Waters and Wastewaters HI93754J-25 Reagents for 25 tests Color of Water 0 to 500 PCU (Platinum Cobalt Units) 1 PCU ±10 PCU ±5% of reading at 25 °C 420 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Colorimetric Platinum Cobalt Method — Copper Low Range 0.000 to 1.500mg/L (as CuÀ+) 0.001mg/L ±0.010mg/L ±5% of reading at 25 °C 575 nm Adaptation of the EPA Method HI95747-01 Reagents for 100 tests HI95747-03 Reagents for 300 tests Copper High Range 0.00 to 5.00 mg/L (as CuÀ+) 0.01 mg/L ±0.02 mg/L ±4% of reading at 25 °C 575 nm Adaptation of the EPA Method HI93702-01 Reagents for 100 tests HI93702-03 Reagents for 300 tests Cyanuric Acid 0 to 80 mg/L (as CYA) 1 mg/L ±1 mg/L ±15% of reading at 25 °C 525 nm Adaptation of the Turbidimetric Method HI93722-01 Reagents for 100 tests HI93722-03 Reagents for 300 tests Fluoride Low Range 0.00 to 2.00 mg/L (as F - ) 0.01 mg/L ±0.03 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, SPADNS Method HI93729-01 Reagents for 100 tests HI93729-03 Reagents for 300 tests Fluoride High Range 0.0 to 20.0 mg/L (as F - ) 0.1 mg/L ±0.5 mg/L ±3% of reading at 25 °C 575 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, SPADNS Method HI93739-01 Reagents for 100 tests HI93739-03 Reagents for 300 tests Hardness, Calcium 0.00 to 2.70 mg/L (as CaCO®) 0.01 mg/L ±0.11 mg/L ±5% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, Calmagite Method HI93720-01 Reagents for 100 tests HI93720-03 Reagents for 300 tests Hardness, Magnesium 0.00 to 2.00 mg/L (as CaCO®) 0.01 mg/L ±0.11 mg/L ±5% of reading at 25 °C 525 nm Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18th Edition, EDTA Colorimetric Method HI93719-01 Reagents for 100 tests HI93719-03 Reagents for 300 tests 11 COD and Vials 11.12 | www.hannainst.com benchtop
RkJQdWJsaXNoZXIy MTI3NTM=